Features:
   Use NDIR technology
    Advanced, dual-wavelength measurement with no moving parts
    Low-power consumption
    Little calibration, high precision ,fast response
    Analog output and RS232 output
    Temperature inside could be for temperature compensate
    Good immunity to other gases and humidity
    Excellent long-term stability  

   Specifications: 
    Method:
     Non Dispersive Infrared (NDIR), gold plated optics,   diffusion sampling

     Performance:
     CO2 measurement Range 0-2000ppm up to 0-5000ppm CO2
     Resolution         10ppm
     Max drift          ±2%FS
     Accuracy           40ppm
     Response time(T90)   <120s
     Repeatability        <1%
     Lifespan             >10 years

     Operating environment:
     Working temperature    0-50℃
     Storage temperature    -20℃- +70℃
     Temperature influent   <0.5%FS per℃
     Working humility       0~95%RH no-condensing

     Inputs and outputs:
     Power supply           DC5V
     Working current        90mA,max 150mA
     Measuring output       linearity output
     Output voltage         0-4VDC
     Digital output         UART Data bit:8; Stop bit:1; Check  bit :null
     Standard baud rate    9600bps
     Dimensions            65*58*14.6mm(L*W*H)


     Fratutes:
      Measuring range:0~5000ppm or 0~10%vol
      Working voltage:DC3.5V~6V,working current:75-80 mA
      Working temperature -20℃~55℃
      Signal output:digital outputanalog outputVoltage of Signal 0.4~2.0V)
      Dimension:Φ20 x 19mm(pin excluded)
      Output interface:5-pin output
      Specificatiom:

Specifications
Working voltage
3.5-6VDC
Working current
75-80mA
Output voltage
0.4V-2VDC
Measurement range
0-0.5% or 0-10%vol
Resolution
Measurement range A: 05000ppm, resolution is 10ppmMeasurement range  B: 0%10%vol  resolution for 0.01%
Warm-up
30s
Response time T90
<25s
Zero repeatability
±1%FS 20
Zero drift
2%/month
Long-term drift
Max  ±3%FS annually
Working temperature
-20-55
Storage temperature
-20-55
Digital signal format
Data bit:8; Stop bit: 1; Check bit: null
Standard baud rate
9600bps
Dimensions
Φ20 x 19mmexcept pin
Output pin
5pin
Lifespan
>5year
Weight
15g 

     Installation Dimension:

     Definition:
     
     Note:
Digital outputTTL electrical levelvoltage signal is 0 or 2.5vpay attention to level switching when connecting external circuit, computer circuit is illustrated below
Baud rate9600bps
Data bit8
Stop bit1
Check bitnull
Power Supply DC3.5V6V
 
Introduction: Gasboard 3000 flue gas analyzer can be used for measurement of the concentration of up to 5 gases such as  SO2, NO,CO, CO2 and O2  components in sample gases simultaneously . It is based on the micro-flow type non-dispersion infrared (NDIR) method for SO2, NO,CO, CO2 and O2  is measured by fuel cell method. This analyzer is designed with 19 inches 3U smaller physical dimensions and the simple single-beam infrared source system.
Features:
  • Up to five gases measurement with micro-flow NDIR gas sensor technology  
  • Simple construction with  Single infrared source and single wavelength
  • 320*240 LCD with menu operation
  • CE Certification constant
  • Sample pump inside optional
  • RS-232 interface
  • Supply data sample control Software for Demo
Specifications:
MeasureGasTechnologyRangeResolutionPrecisionRepetitionError
SO2Micro-flow NDIR2000PPM1PPM≤1%≤1%
NOMicro-flow NDIR2000PPM1PPM≤1%≤1%
COMicro-flow NDIR5000PPM1PPM≤1%≤1%
CO2Micro-flow NDIR25%0.01%≤1%≤1%
O2Electrochemical25%0.01%≤3%≤2%
Note: Measurement range can be customized by the requirement.
 
Gas flow0.7 ~ 1.2 L/min
Pressure of gas inlet<1Bar
Sampling gas requirementRemove water vapor,dust(<1um) and oil etc.
Response Time(TD+T90)<10s (NDIR)
Warm-up Time15min
Communication InterfaceRS232/RS485
Output4~20 mA
AlarmAlarm
 
Work Temperature0~50℃
Relative Humidity5~85%
Ambient Pressure86~108kPa
Power Source Supply220V±44V AC 50Hz±1Hz
Dimension433mm×420mm×132mm(width×length×height)
Weight12kg
Front & Back Panels:
1 Power on/off   2  LCD    3  Left keypad    4  Up keypad    5  Right keypad    6 Down keypad    7  ESC       8  ENT    9  Flow    10 Gas inlet    11 Gas outlet      12 DIO1    13 RS232 interface    14 DIO2    15 GND    16 Power source socket
Applications:The general application is Continuous Emission Monitoring System(CEMS), combustion efficiency monitoring for various industrial furnaces or refuse incinerator and boiler.
      
Flue gas monitoring system(CEMS)                     
 
Infrared flue gas analyzer. Template Design By: BLACKSPIDER